Among
such may be named the detection of traces of phosphine in acetylene which
has passed through a purifier with a view to ascertaining if the
purifying material is exhausted, and the estimation of the amount of air
or other diluents in stored acetylene or acetylene generated in a
particular manner. Advice on these points should be sought from competent
analysts, who will already have the requisite information for the
carrying out of any such tests, or know where it is to be found. The
analyses in question are not such as can be undertaken by untrained
persons. The text-book on "Gas Manufacture" by one of the authors gives
much information on the operations of gas analysis, and may be consulted,
along with Hempel's "Gas Analysis" and Winkler and Lunge's "Technical Gas
Analysis."
APPENDIX
DESCRIPTIONS OF A NUMBER OF ACETYLENE GENERATORS AS MADE IN THE YEAR 1909
(_The purpose of this Appendix is explained in Chapter IV., page 111,
and a special index to it follows the general index at the end of this
book._)
AMERICA--CANADA.
_Maker_: SICHE GAS CO., LTD., GEORGETOWN, ONTARIO.
_Type_: Automatic; carbide-to-water.
The "Siche" generator made by this firm consists of a water-tank
_A_, having at the bottom a sludge agitator _N_ and draw-off
faucet _O_, and rigidly secured within it a bell-shaped generating
chamber _B_, above which rises a barrel containing the feed chamber
_C_, surmounted by the carbide chamber _D_.