SEARCH
0-9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Prev | Current Page 542 | Next

"Acetylene, the Principles of Its Generation and Use"

Other tests showed that the duty increased more considerably
with an increase of pressure, so that mantles used, or which had been
previously used, at a pressure of 5 inches gave duties of 115 to 125
candles per cubic foot.
It should be noted that the burners so far considered are small, being
intended for domestic purposes only; larger burners exhibit higher
efficiencies. For instance, a set of French incandescent acetylene
burners examined by Fouche showed:
_________________________________________________________________
| | | | | |
| Size of Burner | Pressure | Cubic Feet | Light in | Candles per |
| in Litres. | Inches. | per Hour. | Candles. | Cubic Feet. |
|________________|__________|____________|__________|_____________|
| | | | | |
| 20 | 5.9 | 0.71 | 70 | 98.6 |
| 40 | 5.9 | 1.41 | 150 | 106.4 |
| 70 | 5.9 | 2.47 | 280 | 113.4 |
| 120 | 5.9 | 4.23 | 500 | 118.2 |
|________________|__________|____________|__________|_____________|
By increasing the pressure at which acetylene is introduced into burners
of this type, still larger duties may be obtained from them:
_________________________________________________________________
| | | | | |
| Size of Burner | Pressure | Cubic Feet | Light in | Candles per |
| in Litres.