The efficiency values in the fifth
column, however, are the mean values calculated so as to include all the
data referring to each burner. Capelle's results have been reproduced
from the original on the basis that 1 _bougie decimale_ equals 0.98
standard English candle, which is the value he himself ascribes to it (1
_bougie decimale_ equals 1.02 candles is the value now accepted).
_____________________________________________________________________
| | | | | |
| Nominal | Best | Actual Consumption | Maximum | Average |
| Consumption,| Pressure| at Stated Pressure. | Light in | Candles per|
| Litres. | Inches. | Cubic Feet per Hour.| Candles. | Cubic Foot.|
|_____________|_________|_____________________|__________|____________|
| | | | | |
| 10 | 3.5 | 0.40 | 8.4 | 21.1 |
| 15 | 2.8 | 0.46 | 16.6 | 33.3 |
| 20 | 3.9 | 0.64 | 25.1 | 40.0 |
| 25 | 3.5 | 0.84 | 37.8 | 46.