216469 BURNER.]
ILLUMINATING DUTY.--The illuminating value of ordinary self-luminous
acetylene burners in different sizes has been examined by various
photometrists. For burners of the Naphey type Lewes gives the following
table:
___________________________________________________________
| | | | | |
| | | Gas | | Candles |
| Burner. | Pressure, | Consumed, | Light in | per |
| | Inches | Cubic Feet | Candles. | Cubic Foot. |
| | | per Hour. | | |
|_________|___________|____________|__________|_____________|
| | | | | |
| No. 6 | 2.0 | 0.155 | 0.794 | 5.3 |
| " 8 | 2.0 | 0.27 | 3.2 | 11.6 |
| " 15 | 2.0 | 0.40 | 8.0 | 20.0 |
| " 25 | 2.0 | 0.65 | 17.0 | 26.6 |
| " 30 | 2.0 | 0.70 | 23.0 | 32.85 |
| " 42 | 2.0 | 1.00 | 34.0 | 34.0 |
|_________|___________|____________|__________|_____________|
From burners of the Billwiller type Lewes obtained in 1899 the values:
___________________________________________________________
| | | | | |
| | | Gas | | Candles |
| Burner.
Pages:
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530