| 50 | 0.20 | 0.60 | 1.50 | 3.30 | 6.45 | ... | ... | ... |
| 100 | 0.05 | 0.15 | 0.35 | 0.80 | 1.60 | 4.95 |12.30 | ... |
| 200 | ... | 0.04 | 0.09 | 0.20 | 0.40 | 1.20 | 3.05 |12.95 |
| 300 | ... | ... | 0.04 | 0.09 | 0.18 | 0.55 | 1.35 | 5.75 |
| 400 | ... | ... | ... | 0.05 | 0.10 | 0.30 | 0.75 | 3.25 |
| 500 | ... | .. | ... | 0.03 | 0.06 | 0.20 | 0.50 | 2.05 |
| 750 | ... | ... | ... | ... | 0.03 | 0.08 | 0.20 | 0.80 |
| 1100 | ... | ... | ... | ... | ... | 0.05 | 0.12 | 0.50 |
| 1500 | ... | ... | ... | ... | ... | 0.02 | 0.05 | 0.23 |
| 2000 | ... | ... | ... | ... | ... | ... | 0.03 | 0.13 |
| 2500 | ... | ... | ... | ... | ... | ... | 0.02 | 0.08 |
| 5000 | ... | ... | ... | ... | ... | ... | ... | 0.03 |
|____________|______|______|______|______|______|______|______|______|
TABLE (E).
Giving the Sizes of Pipe which should be used in practice for Acetylene
Mains when the fall of pressure in the Main is not to exceed 1.0 inch.
(Based on Morel's formula.)
__________________________________________________________________
| | |
| Cubic feet | |
| of | |
| Acetylene |Diameters of Pipe to be used up to the lengths stated|
| which the | |
| Main is | |
| required |_____________________________________________________|
| to pass | | | | | | | | | |
| in One | 3/4 | 1 |1-1/4|1-1/2|1-3/4| 2 |2-1/2| 3 | 4 |
| Hour |inch.