Apparatus which is supposed to be automatic should be made perfectly
automatic, the water or the carbide-feed being locked automatically
before the carbide store, the decomposing chamber, or the sludge-cock can
be opened. The generating chamber must always be in communication with
the atmosphere through a water-sealed vent-pipe, the seal of which, if
necessary, the gas can blow at any time. All apparatus should be fitted
with rising holders, the larger the better. Duplicate copies of printed
instructions should be demanded of the maker, one copy being kept in the
generator-house, and the other elsewhere for reference in emergencies.
These instructions must give simple and precise information as to what
should be done in the event of a breakdown as well as in the normal
manipulation of the plant. Technical expressions and descriptions of
parts understood only by the maker must be absent from these rules.
ADDENDUM.
BRITISH AND FOREIGN REGULATIONS FOR THE CONSTRUCTION AND INSTALLATION OF
ACETYLENE GENERATING PLANT
Dealing with the "conditions which a generator should fulfil before it
can be considered as being safe," the HOME OFFICE COMMITTEE of 1901
before mentioned write as follows:
1.